X24 Troubleshooting
63
7.4.1 System Faults
7.4.2 Power Supply/Cooling Faults
Symptom
Cause
Action
1
The SYSTEM LED will
illuminate AMBER on
the LRC
2
Audible Alarm sound
The ESI processor
has detected an
internal fault (e.g.
failure of an
internal
communications
path)
1
Check for other AMBER LED indications on the
Power Supply/Cooling modules. If there is a
PSU error present there may be a
communications problem with that Power
Supply/Cooling module. Remove and then re-fit
the module, if the problem persists then change
the module.
2
Check for other AMBER LED indications on the
drives carriers. If none are evident then there
may either be an ESI processor problem or a
Backplane problem.
3
Change the Ops Panel module (see
7.12.2
).
Symptom
Cause
Action
1
Ops Panel
FAULTLED AMBER
2
An AMBER LED on
one or more Power
Supply/Cooling
Modules.
3
Audible Alarm
Sounding.
1
Any power
fault.
2
A fan failure.
3
A thermal
condition
which could
cause PSU
overheating.
1
Check Power On/Off Switch on rear of Power
Supply/Cooling module is switched ON.(not
accessible on later models)
2
Check AC Mains Connections to Power Supply/
Cooling module is live.
3
Disconnect the Power Supply/Cooling module
from mains power and remove the module from
the system, Re-install: if problem persists,
replace Power Supply/Cooling Module.
4
Reduce the ambient temperature.
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...