Configuring X24
191
2
Select
Shutdown/Restart
and press
Enter
The system confirms that you want to shut down
3
.Select
Yes
and press
Enter
.
The system confirms that it has shut down.
To restart the SM, press
Enter
to restart.
The system performs its self-test. When you see the Disk Array Administrator initial screen, the SM is
ready.
G.1.2 Shutting Down the Other SM Module
You should shut down the other SM module when you need to remove the other SM module. This shut
down is the same as unlocking the handles on the SM module hardware to remove it. Using the shutdown
from the Disk Array Administrator lets you see any messages related to the shut down. You cannot see
the messages when you unlock the hardware handles.
You should shut down both SM modules when you need to power down the whole system for
maintenance, repair, or a move. For more information, see
G.1.3, ”Shutting Down Both SM Modules”, on
page 192
.
We strongly recommend that you shut down the SM module gracefully and do not turn off the power. A
normal shutdown ensures that the write-back cache is flushed to the disk.
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...