X24 Troubleshooting
81
7.16 Setting Up and Viewing the Debug
Log
You can set up additional logging when instructed by X24’s technical support personnel.
7.16.1 Summary of Debug Log Capabilities
• Single controller debug information:
available from the Disk Array Administrator via the serial port
on each controller module. Because of the direct connection of the serial port to a storage controller,
debug information from this port can sometimes provide information unavailable from the Ethernet
port, but this information will only be from one storage controller of the redundant storage controller
pair. This information is available as long as one individual controller can boot, read its flash memory
and communicate with it’s serial port.
• Combined log debug information:
available through the SAM via the Ethernet port on each
controller module.
This set of logs will have several advantages over the single controller logs, but will also have a
limitation in that collecting all the log data and passing it out via the Ethernet port requires a greater
amount of hardware/software to be operational than for the single controller serial port case.
Therefore, in some product failure scenarios the combined logs will potentiality have some holes in
the debug data and it will also be necessary to review the single controller logs.
Use the following procedure to collect all three logs:
7.16.2 Collecting Debug Logs
For most problem scenarios you should collect
three
logs, a combined log from one of the two SAM
Ethernet port connections and a single controller log from each of the two Disk Array Administrator local
serial port connections.
Note
If one of the redundant controllers is down we recommend that you restart that Storage Manager module,
if possible, before collecting the debug logs.
SDRAM
UNCORR ECC
A non correctable multiple-bit cache
memory ECC error occurred.
Contact your Supplier.
VOLT/TEMP FAIL The analog-to-digital convertor
monitored a temperature or voltage
in the failure range.
Check that the X24 Subsystem’s fans are
running. Check that the ambient
temperature is not greater than 40°C. If
the Power Supply/Cooling modules have
no errors, replace the SM module where
the error occurred.
Table 7–5
Error events (Continued)
Event
Definition
Recommended Action
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...