Configuring X24
211
To upgrade the LAN Subsystem’s firmware:
1
Check the version of LAN firmware you have now by pressing
CTRL-E
until the configuration information
screen with that information displays.
2
Call technical support for information about downloading the firmware updates.
3
From the computer connected to the SM module, access the DOS window.
4
At the DOS prompt change to the directory where you downloaded
the.bfl file.
5
Enter:
ftp [SM module’s IP address]
6
At the User prompt enter:
flash
7
At the Password prompt enter:
flash
8
At the FTP prompt enter:
bin
9
At the FTP prompt enter:
put [.bfl file name] flash
If you are using Windows 95 or 98, you will see a timeout message (Connection closed by remote host),
but the ftp process is continuing. You can ignore the timeout message. Wait a few minutes and check the
firmware version.
If you are using another operating systems, you will see the downloading progress displayed on the
screen.
10
When you see the restarting message, wait 60 seconds.
11
Check the version of LAN firmware you have now to make sure the firmware update worked by pressing
CTRL-E
until the configuration information screen with that information displays.
12
Repeat steps
3
through
11
on the other SM module.
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...