Managing Arrays & Partitions
149
To set up InfoShield:
1
Display the partition menu.
2
Select
InfoShield
and press
Enter
.
The InfoShield menu displays and shows the current InfoShield type at the top. The default setting for
each partition LUN is Include All Hosts. This results in all hosts being able to access all partitions. You
can change the list type using the Change InfoShield Type option. See the next step.
3
Select the option you want and press
Enter
.
From the Array Menu
From the All Partitions Menu
1
From the System Menu, select
Array
Menu
and press
Enter
.
The Select Array screen displays with a list
of existing arrays.
2
Select the array you want and press
Enter
.
The array menu displays.
3
Select
Partition Menu
and press
Enter
.
The Select Partition screen displays with a
list of existing partitions for the current
array.
4
Select the partition you want and press
Enter
.
The partition menu displays.
1
From the System Menu, select
All
Partitions Menu
and press
Enter
.
The Select Partition or Free Area
screen displays with a list of existing
partitions and free space.
2
Select the partition you want and
press
Enter
.
The partition menu displays.
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...