Managing Drives & Enclosures
187
F.2.2 Changing the Additional EMP Setting
You can change one additional EMP setting:
•
Polling interva
l: This is the interval, in seconds, that the X24 Subsystem polls the EMPs for status
changes. If the polling rate is set to zero, the X24 Subsystem does not communicate with the EMP.
Only use this setting if you suspect you are having communication problems with the EMP. The
default setting is five seconds. A change to this setting on either SM is automatically updated on the
other SM.
To change the EMP settings:
1
From the System Menu, select
Configuration Menu
and press
Enter
.
The Configuration Menu displays.
2
Select EMP
Configuration
and press
Enter
.
The EMP Configuration screen displays.
3
Selec
t EMP Settings
and press
Enter
.
The Poll Rate screen displays.
4
Enter the poll rate you want, in seconds, and press
Enter
.
The system confirms that you want to make the changes.
5
Select
Yes
and press
Enter
to make the changes.
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...