RS-1600-X24 User Guide
12
1.6.4 PSU Safety and EMC Compliance
1.6.5 Power Cord
(minimum requirements)
1.6.6 Environment
Safety Compliance
UL 60950
IEC 60950
EN 60950
EMC Compliance
CFR47 Part 15B Class A
EN55022
EN55024
Cord Type
SV 0r SVT, 18 AWG minimum, 3 conductor
Plug
250V, 10A
Socket
IEC 320 C-14, 250V, 15A
Table 1–2
Ambient Temperature and Humidity
Temperature Range
Relative Humidity
Max. Wet Bulb
Operational
5°C to 40°C
20% to 80%
non-condensing
23°C
Non-Operational
0°C to +50°C
8% to 80%
non-condensing
27°C
Storage
1°C to +60°C
8% to 80%
non-condensing
29°C
Shipping
-40°C to +60°C
5% to 100%
non-precipitating
29°C
Altitude, Operational
0 to 3047 m (0 to 10,000ft)
Altitude, Non-Operational
-305 to 12,192m (-1000 to 40,000ft)
Shock, Operational
Vertical axis 5g peak 1/2 sine, 10ms
Shock, Non-Operational
30g 10ms 1/2 sine
Vibration, Operational
0.21grms 5-500 Hz Random
Vibration, Non-Operational
1.04grms 2-200 Hz Random
Vibration, Relocation
0.3g 2-200 Hz sine
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...