Operation
15
Chapter 2
Operation
2.1 Before You Begin
Before powering up your RS-1600-X24 enclosure please ensure that all the modules are firmly seated in
their correct bays.
2.2 Power On
Do not operate the Subsystem until the ambient temperature is within the specified operating range. If
the drives have been recently installed ensure they have had time to acclimatize before operating them.
Note
Please refer to Section
2.3
for details of the Ops Panel LEDs and related fault conditions.
Follow the procedure below to power up the enclosure.
1
Apply AC Mains power to the enclosure. Turn the Power Supply/Cooling modules to ON.
2
On the Ops Panel, the Audible Alarm beeps once, all LEDs flash for 7 seconds then the Alarm double
beeps.
3
All LEDs on the Ops Panel should be lit (Green) when the enclosure power is activated (and the disk drive
motors should start).
Note
All LEDs on the Ops Panel should be lit Green at power up to indicate that the system is functioning
correctly. If any show Amber then a problem exists and the procedure in
Chapter 4
, ”System Status”, on
page 33
should be followed.
Important
If mains power is lost for any reason, on restoration of power the enclosure will re-start
automatically.
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...