RS-1600-X24 User Guide
62
7.4 Troubleshooting
The following sections describe common problems, with possible solutions, which can occur with your
RS-1600-X24 system
Table 7–2
Ops Panel LED States
Ops Panel LEDs
Other Associated
LEDs or Alarm
State Description
Power
(Green)
PSU/
Cooling/
Temp
(Amber)
System
(Amber)
Address
Mode
Error
(Amber)
FC-X24
Loop
Speed
Hub
Mode
Selected
On
Off
Off
Off
Off
Off
5V Aux present, overall power failed
On
On
On
On
On
On
single beep, then
double beep
Ops Panel power On (5s) test state
On
Off
Off
Off
Power On, all functions good
On
On
Off
PSU LEDs or Fan
LEDs
Any PSU fault or Fan fault
On
On
Flash
Over or Under temperature
On
Off
On
ESI LED on LRC
ESI processor A Failed
On
Off
On
ESI LED on LRC
ESI processor B Failed
On
Off
On
None
• Unknown (invalid or mixed)
LRC module type installed, or
• I2C Bus Failure (inter ESI
processor), or
• Backplane autostart watchdog
failed.
On
Flashing Flashing
PSU Removed
PSU removed and System power
redundancy check option set. No
indication if option not set.
On
Off
Flashing
No SES Drives fitted
On
Flashing
On
Intermittent
audible alarm
Ops to ESI Communications failed
On
Flashing
Invalid address mode setting
(change thumb wheel to valid
ranges)
On
On
2Gb FC-X24 Drive loop speed
selected
On
On
RAID ONLY
Host side
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...