![Ihse Draco tera enterprise 480 Series User Manual Download Page 271](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699271.webp)
Draco tera enterprise
Configuration via Management Software
271
8. Click
Extender & Devices > CPU Devices
in the task area of the Sub Matrix.
8.1. Click
New Device
.
A switchable CPU Device will be created.
8.2. Enter an appropriate name for the Cascading CPU Device into the
Name
field.
Fig. 187 Management software menu
Extender & Devices > CPU Devices - Cascading CPU Device
8.3. Select the previously configured Cascading CPU Unit in the
Extender available
list.
8.4. Click to move the highlighted Cascading CPU Unit to the
Extender assigned
list.
The assignment is displayed in the
Extender assigned
list.
8.5. Click
Apply
to confirm the assignment.
9. Click
Deactivate Edit Mode
in the toolbar.
10. Restart all I/O boards (see chapter 12.2.3, page 320) on which any Master/Sub CON Units or
CPU Units have been configured or alternatively restart the matrix (see chapter 12.2.1, page 318).
11. Connect the Tie Lines to the matrices. Ensure that each
Cascade CON Device
on one matrix is
connected to
Cascade CPU Device
on the other matrix to achieve switching ability between two
matrices.
The Matrix Cascading is now configured and can be used.
Additional Tie Lines are configured accordingly. The use of cascading is described in in chapter 8.1.1,
page 290.