Maintenance
Draco tera enterprise
330
To exchange a fan tray, proceed as follows:
1. Unlock the locking screws.
2. Press the remove button.
The Hot-Swap LED starts flashing. When the Hot-Swap LED illuminates solid, the fan tray is ready to
be removed.
3. Hold the handles and pull out the fan tray.
4. Push a new or maintained fan tray into the slot.
5. Lock the fan tray accordingly.
The fan tray will be recognized by the system and can be used afterwards.
13.1.6 Replacing Air Filters
NOTICE
Risk of overheating
Accumulated dust in the filter pads can decrease the air flow in the chassis. Therefore, the temperature of
the matrix can be overheated.
Check the filter pads regularly for accumulated dust.
Clean the filter pads with low pressure compressed air or suction.
Do NOT exceed an inspection cycle of 6 months.
Depending on the ambient air, the inspection has to be done in a shorter cycle.
Replace filter pads or filter trays at regular intervals of no more than one year.
The air filter can be removed by pulling the air filter's handle. To re-install, push the air filter into the guide
rails at each side of the shelf regarding the labeled orientation mark until the spring mounted ball lock
engage.