![Ihse Draco tera enterprise 480 Series User Manual Download Page 369](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699369.webp)
Draco tera enterprise
Maintenance
369
Option
Description
Expand Tree View
Expand the tree view to show detailed information. This allows to select or
deselect individual firmware to be updated.
Collapse Tree View
Collapse the tree view to hide detailed information. An individual selection of
firmware to be updated is not possible.
Select All
Select all available firmware to be updated
Deselect All
Select all selected firmware
To update the extender module firmware via sequential update, proceed as follows:
1. Click
Status & Updates > Update - Extender Firmware
in the task area.
2. Click
Activate Edit Mode
in the toolbar.
3. Select the
Sequential Mode
option in the upper part of the working area.
All updateable firmware will be automatically selected and highlighted in green.
4. Click
Update
in the lower part of the working area to start the update.
In Sequential Mode the extender module that is being updated is set into the Service Mode, all others
continue to run and can be used. The I/O boards are not affected and continue to run. An OSD picture
indicates the activation of the Service Mode and is displayed on the monitor connected to the CON Unit that
is currently updated.
After update completion of the respective extender module, the Service Mode of the extender module
will be quit.
5. After the update, check the messages in the message box to ensure that the updates for all extender
modules were installed correctly.
Fig. 273 Management software menu
Status & Updates - Update Extender
Firmware - Sequential Mode
6. Click
Deactivate Edit Mode
in the toolbar.