Draco tera enterprise
Installation
63
5.3.1 Connecting a Sink (Console) to the Matrix
1. Connect the monitor(s), keyboard, and mouse to the CON Unit.
2. Connect the CON Unit to an I/O port of the matrix by using interconnect cables (Cat X or fiber).
3. Connect the CON Unit to the power supply unit(s)/power socket(s).
4. Establish the power supply voltage to the CON Unit.
5. Check the basic function of the CON Unit by opening the OSD via keyboard command Hot Key, o.
It is recommended to rename the automatically created EXT Unit directly (see chapter 6.5.1.2, page 101 or
5.3.2 Connecting a Source to the Matrix
1. Connect a source to the CPU Unit by using the provided connection cables.
2. Connect the CPU Unit to an I/O port of the matrix using interconnect cables (Cat X or fiber).
3. Connect the CPU Unit to the power supply unit(s)/power socket(s).
4. Establish the power supply voltage to the CPU Unit.
It is recommended to rename the automatically created EXT Unit directly (see chapter 6.5.1.2, page 101 or