![Ihse Draco tera enterprise 480 Series User Manual Download Page 368](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699368.webp)
Maintenance
Draco tera enterprise
368
Performing the Update in Sequential Mode (Expert Update)
In the Sequential Mode, individual firmware to be updated can be selected/deselected in this menu.
Fig. 272 Management software menu
Status & Updates - Update Extender
Firmware - Sequential Mode
The following information is displayed in the working area:
Option
Description
ID
Numerical value of the extender module ID
Name
Name of the EXT Unit and the extender module firmware
Port
Port number of the matrix, the extender module is physically connected
Type
Type of the CON/CPU Unit and firmware type
Device
Name of the CON Device/CPU Device the EXT Unit is assigned to
Current Version
Installed firmware version
Update Version
Firmware version available for the update
Update
Select/deselect for firmware update
Firmware types to be updated or firmware conflicts are highlighted in color:
Extender firmware version conflict
Manual update of EXTMSD/EXTIMSD recommended*
Wrong module (CPU/CON mismatch)
Undefined type
* Only for firmware versions older than V2.25 (EXTMSD) and V1.13 (EXTIMSD) and only if instructed by the
manufacturer's technical support or if the release notes indicate dependencies between extender module
firmware files. EXT*MSD requires manual update via the Mini-USB service port at the extender modules.