7.11.4 Uploading a Predefined Configuration to the Matrix
Using the function
Upload
, the configuration can be saved within eight storage locations in the matrix
(
File#1
to
File#8
). However, it does not replace the buffering of configuration (see chapter 7.11.1,
page 274).
Additionally, a configuration can also be saved as default configuration that can be automatically loaded
with each start (for activation of this function see chapter 7.4.1, page 151.
To upload an opened configuration to the matrix, proceed as follows:
1. Click
Upload
in the toolbar.
An access window appears.
2. Enter the IP address of the matrix.
3. Enter the username and password of the administrator.
4. Click
Next >
.
Fig. 192 Management software menu
Upload - Connect
5. Under
Select Configuration Slot
, select the storage slot for the configuration (
default
or
config01
to
config08
).
6. Option: to activate the uploaded configuration immediately, tick the
Activate configuration after
upload
checkbox.
NOTICE
If you tick the
Activate configuration after upload
checkbox, the matrix will be restarted immediately
after the save process has been completed. The restart of the matrix may take several minutes, and the
matrix is not available during the restart.