![Ihse Draco tera enterprise 480 Series User Manual Download Page 91](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699091.webp)
Draco tera enterprise
Configuration via OSD
91
Real Time Clock
Field
Entry
Description
Date*
MM
1 to 12
Enter the month.
DD
1 to 31
Enter the day.
YY
1 to 99
Enter the year.
Day
1 to 7
Enter day of the week.
Time
hh
0 to 23
Enter the hour.
mm
0 to 59
Enter the minute.
dd
0 to 59
Enter the second.
* Date format according to the English notation.
Configuring the Time Server
To configure a time server, proceed as follows:
1. Select
Configuration > Date+Time
in the main menu.
2. Set the SNTP Client option to
Y
(Yes).
3. Enter the IP address of your SNTP server into the
SNTP Server
field.
4. Select your time zone in the
Time Zone
field.
5. Click
Okay
to confirm your settings.
6. Restart the matrix.
The system time will now be provided by the SNTP server.
Configuring the Real Time Clock without Time Server
To set the real time clock without using SNTP, proceed as follows:
1. Select
Configuration > Date+Time
in the main menu.
2. Set the current date in the
Date
field.
3. Set the current Day in the
Day
field.
4. Set the current time in the
Time
field.
5. Click
RTC
to confirm your settings.
The real time clock is now provided.