Draco tera enterprise
Installation
67
5.4.5 Connecting to the Matrix with known IP Address
At least power user rights are required, and the API function have to be enabled.
Up to 16 connections between the matrix and the management software can be established at the same
time due to a limitation of available sockets.
To connect to a matrix when the IP address is known, proceed as follows:
1. Run the management software.
2. Click
Connect
in the tool bar.
A login dialog appears.
3. Enter the IP address according to the network configuration of the matrix (see chapter 7.4.8, page 166).
By default, the IP address of the matrix is 192.168.100.99 and DHCP is deactivated.
4. Enter the username and password of the administrator (see chapter 7.5, page 182).
By default, the username is admin, and the password of the administrator is admin.
5. Click
Login
to confirm your entries.
Fig. 47
Management software dialog
Connect
The data must be entered each time the network connection is re-established.
Alternately, the data can be entered and stored in the management software under
Extras > Options
(see chapter 7.3.1, page 147).