Configuration via OSD
Draco tera enterprise
106
6.5.4 Configuring EXT Units for SDI Usage
For the use of SDI, the matrix is to be configured in this menu. Using SDI requires at least one UNI I/O
board and appropriate SFP modules according to the SDI video signal to be used.
Fig. 68
OSD Menu
Configuration - EXT Units - Uni board - Configuring SDI
To configure an SFP for using as an SDI input/output, proceed as follows:
1. Select
Configuration > EXT Units
in the main menu.
2. Insert the SFP modules into the matrix and connect the extender module according to the required
application.
One EXT Unit will be created for each SFP module in the
EXT Units
list. The appropriate names
always start with “UNI”.
In the sub menu
EXT Type
,
Universal-CON
and
Universal-CPU
are set to
Y
.
3. To configure an EXT Unit as an SDI input:
3.1. Select one of the extender modules in the
EXT Units
list that corresponds to the respective SFP
and is intended to be used as input.
3.2. Set the
Universal-CPU
option to
Y
(
C#1
in the Output
Signals
column.
3.3. Set additionally the
Universal-CON
option to
N
(
C#1
in the
Input Signals
column.
3.4. Click
Okay
to confirm the setting.