![Ihse Draco tera enterprise 480 Series User Manual Download Page 123](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699123.webp)
Draco tera enterprise
Configuration via OSD
123
6.7.5 Setting CON Device Macros
In this menu macro commands for switching, disconnection or user administration can be created. The
macro commands are created for each CON Device separately. Up to 32 macros can be configured for
each CON Device. A macro can execute up to 16 switching commands successively.
The execution of the macros is done via Hot Key and the function keys F1 to F16 (see chapter 8.1.4,
page 293).
The macros can also be used to switch to CPU groups.
Fig. 79
OSD Menu
Configuration - CON Macros
The following parameters can be configured:
Field
Selection
Description
Function
(01 to 16)
Connect
(P1=CON, P2=CPU)
Set a bidirectional connection from CON Device P1 to CPU
Device P2.
Connect Video
(P1=CON, P2=CPU)
Set a Video Only connection from CON Device P1 to CPU
Device P2.
Disconnect
(P1=CON)
Disconnect the CON Device P1.
Logout User
Logout the current user.
Assign CPU
(P1=VCPU, P2=RCPU)
Assign a virtual CPU Device to a real CPU Device.