The following parameters can be configured:
Field
Entry
Description
ID
Text
Ident number of the CPU Device.
Name
Text
Name of the CPU Device.
Member of Switch
Selection
Assign the CPU Device input to the respective CPU Switch.
Switch
Y
Automatically set for a CPU Switch (484 Series).
N
Function not active (default).
Further parameters are described in chapter 6.6.1, page 108.
To configure the CPU Switch for an individual switching of the single inputs, proceed as follows:
1. Select
Configuration > CPU Devices
in the main menu.
2. Click
New S.
.
A new CPU Switch will be created.
3. Enter a CPU Switch name into the field
Name
.
4. Assign an EXT Unit to the CPU Switch into the field
EXT assigned
.
5. Click
New SP.
.
A new CPU Device (input) for a CPU Switch will be created (Port 1).
6. Assign the created CPU input to a CPU switch in the field
Member of Switch
.
7. Repeat the steps 5. and 6. for each input port in use at the CPU Switch.
8. Click
Okay
.