![Ihse Draco tera enterprise 480 Series User Manual Download Page 318](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699318.webp)
Operation via Management Software
Draco tera enterprise
318
12.2 Restarting and Powering down Functions via Management Software
NOTICE
Possible damage of boards or the matrix
The file system check phase when the matrix is restarted (indicated with 2x white LEDs) is a very
sensitive process.
If the matrix is switched off while restarting, the respective boards may be damaged in its function.
DO NOT power off the matrix while the file system is being checked.
NOTICE
Possible loss of the current configuration
If the matrix is restarted or shut down (indicated with 1x off/1x yellow LEDs), the current configuration is
saved.
If the matrix is powered off while shutting down or restarting, the matrix may restart with factory settings.
DO NOT power off the matrix while shutting down or restarting.
12.2.1 Restarting the Matrix
To perform a restart of the matrix, proceed as follows:
1. Click
Device > Advanced Service > Restart Device
in the menu bar.
An access window appears.
2. Enter the username and password of the administrator.
3. Click
Ok
.
Fig. 223 Management software dialog
Log in administrator
A query to restart the matrix appears.
4. Click
Yes
to restart the matrix.
Fig. 224 Management software dialog
Restart Matrix
The current configuration is saved in the permanent memory of the matrix and the matrix will be
restarted.