806f020d-2b840818
Failure Predicted on [NumericSensorElementName] for array
[ComputerSystemElementName].
Explanation:
The eXFlash Proxy Service reported a failure predicted (PFA) on the eXFlash DIMM 24 in Compute
Book 4.
May also be shown as 806f020d2b840818 or 0x806f020d2b840818
Severity:
Warning
Alert Category:
System - Predicted Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0168
SNMP Trap ID:
27
Automatically notify Support:
Yes
User response:
At the next maintenance opportunity:
1.
Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.
2.
If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash DIMM is properly
seated and visually verify that there is no foreign material in any DIMM connector on that memory channel. If
either of these conditions is found, correct and retry with the same eXFlash DIMM. (Note: Event Log may contain
a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem.)
3.
Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error.
4.
If problem persists and there are no other eXFLash DIMMs with the same indication, confirm that the eXFlash
DIMM is under warranty before replacement.
Related Links:
v
“Server features and specifications” on page 7
v
“Removing a DDR3 compute book” on page 283
v
“Replacing a DDR3 compute book” on page 284
v
“Removing the DDR3 compute book cover” on page 218
v
“Replacing the DDR3 compute book cover” on page 220
v
“Removing a memory module” on page 239
v
“Replacing a memory module” on page 240
v
“Flash DIMMs” on page 51
806f0221-0b01ffff
Package installed in slot [PhysicalConnectorElementName] for system
[ComputerSystemElementName].
Explanation:
IMM has detected that a card was was Installed in a PCIe slot 1.
May also be shown as 806f02210b01ffff or 0x806f02210b01ffff
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0334
SNMP Trap ID:
Automatically notify Support:
No
User response:
Information only; no action is required.
806f020d-2b840818 • 806f0221-0b01ffff
850
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Summary of Contents for X3850 X6
Page 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Page 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1729: ......
Page 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...