806f0207-2583ffff
[ProcessorElementName] has Failed with FRB1/BIST condition.
Explanation:
IMM has reported a microprocessor Failed - FRB1/BIST condition.
May also be shown as 806f02072583ffff or 0x806f02072583ffff
Severity:
Error
Alert Category:
Critical - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0044
SNMP Trap ID:
40
Automatically notify Support:
Yes
User response:
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
Related Links:
v
“Finding the UEFI (POST) error code” on page 1666
806f020d-0400ffff
Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].
Explanation:
Failure predicted (PFA) on the hard drive 0.
May also be shown as 806f020d0400ffff or 0x806f020d0400ffff
Severity:
Warning
Alert Category:
System - Predicted Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0168
SNMP Trap ID:
27
Automatically notify Support:
Yes
User response:
Replace the hard disk drive at the next maintenance period.
Related Links:
v
“Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231
v
“Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232
806f020d-0401ffff
Failure Predicted on [NumericSensorElementName] for array [ComputerSystemElementName].
Explanation:
Failure predicted (PFA) on the hard drive 1.
May also be shown as 806f020d0401ffff or 0x806f020d0401ffff
Severity:
Warning
Alert Category:
System - Predicted Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0168
SNMP Trap ID:
27
Automatically notify Support:
Yes
User response:
Replace the hard disk drive at the next maintenance period.
Related Links:
v
“Removing 2.5-inch and 1.8-inch hot-swap drives” on page 231
v
“Replacing 2.5-inch and 1.8-inch hot-swap drives” on page 232
806f0207-2583ffff • 806f020d-0401ffff
Appendix B. Integrated management module II (IMM2) error messages
781
Summary of Contents for X3850 X6
Page 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Page 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1729: ......
Page 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...