v
“Solving power problems” on page 197
v
“Installing power supplies” on page 104
806f0a07-0303ffff
[ProcessorElementName] is operating in a Degraded State.
Explanation:
The microprocessor 3 is being throttled due to thermal or power conditions.
May also be shown as 806f0a070303ffff or 0x806f0a070303ffff
Severity:
Warning
Alert Category:
Warning - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0038
SNMP Trap ID:
42
Automatically notify Support:
No
User response:
Check the IMM event log for any fan, cooling, or power related issues.
For a thermal condition:
1.
Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and
correctly installed.
2.
Make sure that the room temperature is within operating specifications.
For a power condition:
1.
If Power Supply Unit is rated 1400 Watt, Make sure it is connected to 220V AC input
2.
If using a 900 Watt rated power supply (connected at either 110V or 220 V ), may need to upgrade to a 1400 Watt
rated power supply (connected at 220V).
Related Links:
v
“Server features and specifications” on page 7
v
“Solving power problems” on page 197
v
“Installing power supplies” on page 104
806f0a07-0304ffff
[ProcessorElementName] is operating in a Degraded State.
Explanation:
The microprocessor 4 is being throttled due to thermal or power conditions.
May also be shown as 806f0a070304ffff or 0x806f0a070304ffff
Severity:
Warning
Alert Category:
Warning - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0038
SNMP Trap ID:
42
Automatically notify Support:
No
User response:
Check the IMM event log for any fan, cooling, or power related issues.
For a thermal condition:
1.
Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and
correctly installed.
2.
Make sure that the room temperature is within operating specifications.
For a power condition:
1.
If Power Supply Unit is rated 1400 Watt, Make sure it is connected to 220V AC input
806f0a07-0303ffff • 806f0a07-0304ffff
Appendix B. Integrated management module II (IMM2) error messages
1161
Summary of Contents for X3850 X6
Page 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Page 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1729: ......
Page 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...