v
Four Scalable Memory Interconnect 2 (SMI2) links per microprocessor at
up to 6.4 GT/s
v
Each microprocessor has four memory channels, each memory channel
has two DDR channels, and each DDR channel supports three DIMMs
v
Intel EX micropro C600 series chipset (PCH)
v
HyperThreading Technology
v
Up to 32 PCIe Gen3 lanes per processor
Note:
v
Use the Setup utility to determine the type and speed of the
microprocessors in the server.
Memory (depending on the model):
v
DIMM connectors: 96 for the 4-socket and 192 for the 8-socket
– Minimum: 8 GB (two 4 GB DIMMs) for the 4-socket and 16 GB (four
4 GB DIMMs) for the 8-socket
– Maximum: 6 TBs (when using all 64 GB DIMMs) for the 4-socket and
12 TBs (when using all 64 GB DIMMs) for the 8-socket
v
Type: PC3-12800R 1600 MHz, PC3L-12800 1600 MHz or PC3L-10600 1333
MHz Load Reduced (LR) single-rank, double-rank, or quad-rank, ECC,
240 pin, DDR3 registered SDRAM DIMMs only
v
Supports standard 4 GB, 8 GB, 16 GB RDIMMs, and 16 GB, 32 GB, and
64 GB LR-DIMMs
v
Supports l.35-volt registered DIMMs (see “Installing a memory module”
on page 47 for more information)
v
The server also supports 200 GB and 400 GB eXFlash DIMMs that you
can install in unused DIMM slots to increase high performance storage
capabilities.
Drive expansion bays (depending on the model):
v
The server supports up to sixteen, drives (depending on the drive
backplane configuration) per 4-socket system. The following types of
drives are supported:
– l.8-inch hot-swap Serial Attached SCSI (SAS) solid state drives (SSD)
– 2.5-inch hot-swap Serial Attached SCSI (SAS) hard disk drives (HDD)
and solid state drives (SSD)
PCI expansion slots (depending on your model):
The server provides up to twelve PCIe adapter slots (with two I/O books
installed), as listed below:
v
The base system provides the following slots:
– Two x16 full-height slots, Gen3, 16 lanes wired (PCIe Gen3, x16)
– One x16 full-height slot, Gen3, 8 lanes wired (PCIe Gen3, x16 (8, 4, 1)
– Two x16 low-profile host bus adapter slots in the Storage book, Gen3,
8 lanes wired each (PCIe Gen3, x16 (8, 4, 1)
– One x8 Gen3 dedicated ML adapter slot, 8 lanes wired (non-standard
PCIe connector)
v
The optional half-length I/O book provides the following slots:
– One x16 full-height slot, Gen3, 16 lanes wired (PCIe Gen3, x16)
– Two x8 full-height slots, Gen3, 8 lanes wired each (PCIe Gen3, x8)
v
The optional full-length I/O book provides the following slots:
– Two x16 full-height slots, Gen3, 16 lanes wired each (PCI3 Gen3, x16)
8
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Summary of Contents for X3850 X6
Page 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Page 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1729: ......
Page 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...