S.58008
[S.58008]
Explanation:
A DIMM has failed the POST memory test. DIMM Failed Memory Test
Severity:
Error
User response:
Complete the following steps:
1.
You must AC-cycle the system to re-enable affected DIMM connector or re-enable manually using F1 setup
2.
If the node has been recently installed, serviced, moved, or upgraded, check to ensure that DIMMs are firmly
seated and that no foreign material can be seen in the DIMM connector. If either condition is observed, correct
and retry with the same DIMM. (Note: Event Log may contain a recent 00580A4 event denoting detected change
in DIMM population that could be related to this problem.)
3.
If problem persists, replace the DIMM identified by LightPath and/or event log entry. If this is a flash DIMM,
make sure it is still under warranty before replacing it.
4.
If problem re-occurs on the same DIMM connector, swap the other DIMMs on the same memory channel across
channels one at a time to a different memory channel or Processor. (check service information for this
product/Install guide for population requirements for sparing/paring modes). If problem follows a moved DIMM
to a different memory channel, replace that DIMM. If this is a flash DIMM, make sure it is still under warranty
before replacing it.
5.
Check IBM support site for an applicable service bulletin or firmware update that applies to this memory error.
6.
If problem stays with the original DIMM connector, re-inspect DIMM connector for foreign material and remove,
if found. If connector is damaged, replace compute book.
7.
(Trained service technician only) Remove affected Processor and inspect Processor socket pins for damaged or
mis-aligned pins. If damage is found, or this is an upgrade Processor, replace the compute book. If there are
multiple Processor’s, swap Processor’s to move affected Procesor to another Processor socket and retry. If problem
follows the affected Processor (or there is only one Processor), replace the affected Processor.
S.58009
[S.58009]
Explanation:
All DIMMs have been disabled and the system will be unable to boot until this is corrected. All DIMM
Slots Disabled
Severity:
Error
User response:
Complete the following steps:
1.
Check system log for related DIMM failures and replace those DIMMs.
S.68005
[S.68005]
Explanation:
An error has been detected by the the IIO core logic on Bus %. The Global Fatal Error Status register
contains %. The Global Non-Fatal Error Status register contains %. Please check error logs for the presence of
additional downstream device error data. Critical IOH-PCI Error
Severity:
Error
User response:
Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update for the system or adapter that
applies to this error.
2.
Check log for a separate error for an associated PCIe device and service that error.
3.
Replace the I/O book reported in the error.
4.
Replace the compute book reported in the error.
S.58008 • S.68005
Appendix C. UEFI/POST error codes
1679
Summary of Contents for X3850 X6
Page 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Page 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1729: ......
Page 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...