Drive
Backplane
Drive Quantity
(Q)
CPU Power (P)
Maximum
Temperature
X6000 V5 C00
24 x 2.5" SAS
backplane
16 < Q ≤ 24
140 W < P ≤ 165 W 30°C (86°F)
P ≤ 140 W
35°C (95°F)
8 < Q ≤ 16
140 W < P ≤ 165 W 32°C (89.6°F)
P ≤ 140 W
35°C (95°F)
0 < Q ≤ 8
P ≤ 165 W
35°C (95°F)
X6000 V5 C10
24 x 2.5"
NVMe
backplane
16 < Q ≤ 24
165 W < P ≤ 205 W N/A
140 W < P ≤ 165 W 30°C (86°F)
P ≤ 140 W
35°C (95°F)
8 < Q ≤ 16
165 W < P ≤ 205 W N/A
140 W < P ≤ 165 W 32°C (89.6°F)
P ≤ 140 W
35°C (95°F)
0 < Q ≤ 8
165 W < P ≤ 205 W 28°C (82.4°F)
P ≤ 165 W
35°C (95°F)
X6000 V5 C10
24 x 2.5" SAS
backplane
16 < Q ≤ 24
165 W < P ≤ 205 W N/A
140 W < P ≤ 165 W 30°C (86°F)
P ≤ 140 W
35°C (95°F)
8 < Q ≤ 16
165 W < P ≤ 205 W 28°C (82.4°F)
P ≤ 165 W
35°C (95°F)
0 < Q ≤ 8
165 W < P ≤ 205 W 32°C (89.6°F)
P ≤ 165 W
35°C (95°F)
X6000 V5 C10
12 x 3.5" SAS
backplane
8 < Q ≤ 12
165 W < P ≤ 205 W N/A
140 W < P ≤ 165 W 30°C (86°F)
P ≤ 140 W
35°C (95°F)
4 < Q ≤ 8
165 W < P ≤ 205 W 30°C (86°F)
140 W < P ≤ 165 W 35°C (95°F)
0 < Q ≤ 4
P ≤ 205 W
35°C (95°F)
FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide
A Appendix
Issue 17 (2021-03-09)
Copyright © Huawei Technologies Co., Ltd.
162