Callout No.
Description
4
Year and month (two characters).
● The first character indicates the year.
– Digits 1 to 9 indicate years 2001 to 2009, respectively.
– Letters A to H indicate years 2010 to 2017, respectively.
– Letters J to N indicate years 2018 to 2022, respectively.
– Letters P to Y indicate years 2023 to 2032, respectively.
NOTE
The years from 2010 are represented by uppercase letters excluding
I, O, and Z because the three letters are similar to digits 1, 0, and 2.
● The second character indicates the month.
– Digits 1 to 9 indicate January to September, respectively.
– Letters A to C indicate October to December, respectively.
5
Sequence number (six characters).
6
RoHS compliance (one character). Y indicates RoHS compliant.
7
Internal model, that is, product name.
A.2 Operating Temperature Limitations
NO TE
For configurations not listed in the table, the operating temperature range is 5°C (41°F) to
30°C (86°F). For special configuration and temperature requirements, contact Huawei
technical support.
A.2.1 Operating Temperature Limitations (Supercapacitor for
the RAID Controller Card Configured)
Table A-2 Operating temperature specifications (with a RAID controller card
supercapacitor configured)
Drive
Backplane
Drive Quantity
(Q)
CPU Power (P)
Maximum
Temperature
X6000 V5 C00
24 NVMe
backplane
16 < Q ≤ 24
P ≤ 165 W
30°C (86°F)
8 < Q ≤ 16
125 W ≤ P ≤ 165 W 30°C (86°F)
P < 125 W
35°C (95°F)
X6000 V5 C00
24 SAS
backplane
16 < Q ≤ 24
125 W ≤ P ≤ 165 W 32°C (89.6°F)
P < 125 W
35°C (95°F)
8 < Q ≤ 16
140 W ≤ P ≤ 165 W 32°C (89.6°F)
FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide
A Appendix
Issue 17 (2021-03-09)
Copyright © Huawei Technologies Co., Ltd.
157