36
Count
Ht:
Exit
Oset
Hold
Hm:
HR:
120°20′00″
120°09′30″
[ 1]
120°20′00″
●
Aim at point ‘B’ again by horizontal motion and
tangent screw and press [F3](Hold);
Count
Ht:
Exit
Oset
Rel.
Hm:
HR:
240°40′00″
120°18′00″
[ 2]
120°20′00″
●
Repeat the steps above until the measurement times
wanted;
●
If want to exit this function ,just press [F2](Exit),then
press [F4](Yes) to return the basic measurement
;
●
Notice: if the angle value compared with the fist
measured is over ±30″, the error massage will
appear.
5.6 Slope (V%)
Function: vertical angle switched with slope (V%).
Every time you press [F3] (V%),the display mode of
vertical angle will be switched each other. When the slop is over
45°
,
it will tip “Over! ”(Over measurement range).
5.7 H-Bz
When horizontal angle is in the range of 0°(90°,180° or
270°)
±
4′30″, the buzzer will beep.