71
Input T.H
Clear
B.S
Enter
T.H:
1.000
6)
Aim at the known point 1, press [F3](Angle) or
[F4](Dist). Press [F4](Dist) for example;
VZ:
HR:
SD:
m
T.H:
No.1
2°09′30″
102°09′30″
1.000 m
Dist
Angle
> Aim at BS?
7)
Start measuring;
VZ:
Measuring…
HR:
SD*
m
T.H:
No.1
2°09′30″
102°09′30″
[Sgnl] <<
1.000 m
8)
Enter the input interface of point 2 ;
Resection
NO.2
Num.
List
B.S
Enter
Pt.n:
2
9)
According to step 5)~step 8), when using [Dist] to
measure, the residual will be calculated.
Resection
Resid.
Next P
Calc
dHD =
dZ =
-0.003
0.001 m
m