[Enter] ,then the system searches the data from the first piece (all
name matched). If searching it, the cursor will be at the point , or
will tip and back to the first piece data.
●press [Del] to enter the interface of “Del”,if select [Yes],
the data you selected will be deleted or press [Exit] back to the
data list.
9.3.2 Import
As the format of file in the instrument is binary, the
External data must be imported to instrument. This function can
import the external ASCII coordinate file and code file to
instrument to save in binary format. The types of file you
selected are distinguished each other by extension. So, you must
be careful about the file type, or you will import unsuccessfully.
The interface of importing file as shown in picture below:
Type of import
1. Import from PC
2. Import from USB
9.3.2.1 Import from PC
This function needs port to connect PC and instrument, but
the transfer software must be installed on the PC to end data, or
the instrument can’ receive. Press [Fileman]→ [2](Import)→
[1.Import from PC],then the interface of “Import data” as shown
below: