Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
706
●
Interface
•
Master IP Link Local Address
•
Master Connect IP Address
•
Slave IP Link Local Address
•
Slave Connect IP Address
Description
Input the link local address (interface ID) for the Master CM of the ETERNUS DX.
Note that the link local address is only available within the same network and cannot be
connected to the Internet. Connection via a router is not available.
Refer to
"Available IPv6 Address" (page 107)
for details.
Note that the current setting is displayed by an abbreviation.
Input condition/
Display contents
fe80::xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (FFFF) (hexadecimal, alphanumeric characters)
Refer to
"IPv6 Address Notation (Setup Network Environment)" (page 107)
for details.
Description
Input the connect IP address for the Master CM of the ETERNUS DX.
"Master Connect IP Address" corresponds to "Master IP Address" for IPv4.
"Global address", "unique local address", or "6to4 address" can be input for the IP
address. Refer to
"Available IPv6 Address" (page 107)
for details.
Note that the current setting is displayed by an abbreviation.
Input condition/
Display contents
xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (FFFF) (hexadecimal, alphanumeric characters)
Refer to
"IPv6 Address Notation (Setup Network Environment)" (page 107)
for details.
Description
Input the link local address (interface ID) for the Slave CM of the ETERNUS DX.
The link local address of the Slave CM is used when an error occurs in the Master CM.
Refer to
"Available IPv6 Address" (page 107)
for details.
This item is not displayed for the 1CM model.
Note that the current setting is displayed by an abbreviation.
Input condition/
Display contents
fe80::xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (FFFF) (hexadecimal, alphanumeric characters)
Refer to
"IPv6 Address Notation (Setup Network Environment)" (page 107)
for details.
Description
Input the connect IP address for the Slave CM of the ETERNUS DX.
The connect IP address of the Slave CM is used when an error occurs in the Master CM.
"Slave Connect IP Address" corresponds to "Slave IP Address" for IPv4.
"Global address", "unique local address", or "6to4 address" can be input for the IP
address. Refer to
"Available IPv6 Address" (page 107)
for details.
This item is not displayed for the 1CM model.
Note that the current setting is displayed by an abbreviation.
Input condition/
Display contents
xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (FFFF) (hexadecimal, alphanumeric characters)
Refer to
"IPv6 Address Notation (Setup Network Environment)" (page 107)
for details.