Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
720
•
Retry Interval
A.1.7.11
Setup Syslog
For details about this function, refer to
"1.8.13 Setup Syslog" (page 132)
.
For the factory default settings for this function, refer to
"Appendix B Setup Syslog" (page 982)
●
Syslog Server1, Syslog Server2
•
Send Log
•
Domain Name / IP Address
•
Port No.
Description
Input the interval between each retry attempt.
Input condition/
Display contents
1 - 300 sec.
Description
Select the Syslog sending parameters.
Logs are sent in the selected RFC message format.
Input condition/
Display contents
•
on (RFC3164)
•
on (RFC5424)
•
off
Description
Input the domain name or the IP address of the Syslog server.
There are two methods to specify an IP address; "IPv4" and "IPv6". The following IPv6
addresses can be used; "link local address", "global address", "unique local address", or
"6to4 address". Refer to
"Available IPv6 Address" (page 107)
for details. When the
current setting is displayed, the IPv6 address is displayed as an abbreviation.
Input condition/
Display contents
•
For IPv4 address
xxx.xxx.xxx.xxx
xxx: 1 - 255 for the top field (decimal)
xxx: 0 - 255 for other fields (decimal)
•
For IPv6 address
xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (FFFF) (hexadecimal, alphanumeric characters)
Refer to
"IPv6 Address Notation" (page 378)
for details.
•
For domain name
Up to 63 alphanumeric characters and symbols
Description
Input the port number used to send a Syslog.
Input condition/
Display contents
•
Numeric characters
•
1 - 65535
Summary of Contents for Eternus DX200F
Page 2: ...This page is intentionally left blank ...
Page 1082: ......