Chapter 1 System Management
1.4 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
39
1.4.4
Setup Subsystem Parameters
This function specifies the subsystem parameters.
Subsystem parameters are the information which controls the ETERNUS DX operation when it is connected to
hosts. The ETERNUS DX operates according to the specified subsystem parameters, for all the hosts to be
connected.
Conditions for changing subsystem parameters
Changing parameters while accessing the host
OK: Parameters can be changed.
N/A: Parameters cannot be changed.
Server reboot
Required: The server must be rebooted after a parameter change.
–: The server does not require a reboot.
For details on the parameters for this function, refer to
"A.1.3.4 Setup Subsystem Parameters" (page 672)
For the factory default settings for this function, refer to
"Appendix B Setup Subsystem Parameters" (page
.
The procedure to set the subsystem parameters is as follows:
Procedure
1
Click [Setup Subsystem Parameters] in [Action].
•
If a change to subsystem parameters is required, the recommended time is when the load is low in the
ETERNUS DX.
•
Some subsystem parameters may require rebooting of the server after changes have been made. Refer to
"Conditions for changing subsystem parameters" (page 39)
for details.
Category
Subsystem parameter
Changing parameters
while accessing the host
Server reboot
Setup Subsystem
Parameters
Thin Provisioning
Allocation Mode
OK
–
Flexible Write Through
OK
–
Turbo Mode
OK
–
Writeback Limit Count
OK
–
Setup Host
Load Balance
OK
–
Reject INQUIRY from
Unauthorized Host
OK
Required
Optimize for Advanced
Format SSD
OK
Required
Setup Disk Drive
Checkcode Enforcement
OK
–
Copybackless
OK
–
Web GUI Settings
Function to Add Host
OK
–