Appendix A Parameter List
A.4 Connectivity Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
850
-
IPv6 Link Local Address
-
IPv6 Connect IP Address
Description
Input the IPv6 link local address of the target port (required when "IPv6" is selected).
"Available IPv6 Address" (page 107)
for details. Note that the current setting
is displayed by an abbreviation.
Click the [Test Connection (ping)] button to display the [Send ping] screen. Specify
the IP address to check the connection status of the connection remote storage
system and the number of transmissions. Click the [Send] button. When the "ping"
command is sent, the settings of the IP address and the connection path for the
remote storage system can be checked.
Click the [Default] button to set the default IPv6 link local address.
Input condition/
Display contents
•
fe80::xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (FFFF) (hexadecimal, alphanumeric characters)
Refer to
"IPv6 Address Notation" (page 378)
for details.
This item is not displayed when the port type is "iSCSI RA (for older storage system connection)".
Description
Input the IPv6 connect IP address of the target port.
"Global address", "unique local address", or "6to4 address" can be input for the IPv6
address. Refer to
"Available IPv6 Address" (page 107)
for details. When the current
setting is displayed, the IPv6 address is displayed as an abbreviation.
"IPv6 Connect IP Address" corresponds to "IP Address" for IPv4.
"IPv6 Connect IP Address" can be directly input or created automatically.
Click the [Discovery] button to display the [Select IPv6 Prefix] screen. Up to five "IPv6
Prefix" can be obtained. Select "IPv6 Prefix" to create an IPv6 connect IP address
automatically from the selected IPv6 prefix and the input IPv6 link local address
(interface ID). Click the [OK] button to specify the created IPv6 address in the entry
field.
Click the [Test Connection (ping)] button to display the [Send ping] screen. Specify
the IP address to check the connection status of the connection remote storage
system and the number of transmissions. Click the [Send] button. When the "ping"
command is sent, the settings of the IP address and the connection path for the
remote storage system can be checked.
Input condition/
Display contents
•
xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx
xxxx: 0 - ffff (FFFF) (hexadecimal, alphanumeric characters)
Refer to
"IPv6 Address Notation" (page 378)
for details.
This item is not displayed when the port type is "iSCSI RA (for older storage system connection)".