Chapter 1 System Management
1.4 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
36
3
Click the [Set] button.
A confirmation screen appears.
If an error screen appears under the following conditions, check the parameter settings.
•
A non-existent date has been specified in the date/time settings
•
"By day of the week" is selected for the range of daylight saving time and the same day and time is
entered for both the start day/time and the end day/time
•
"By Date" is selected for the range of daylight saving time and the same day and time is entered
for both the start day/time and the end day/time
•
"By Date" is selected for the range of daylight saving time and a non-existent date is specified as
the start date
•
"By Date" is selected for the range of daylight saving time and a non-existent date is specified as
the end date
•
"Yes" is selected for "Synchronize with NTP Server" and the domain or the IP address is not entered
for the primary NTP server
•
"Yes" is selected for "Synchronize with NTP Server" and the same domain or IP address is specified
for the primary NTP server and the secondary NTP server
•
"Yes" is selected for "Synchronize with NTP Server", the LAN port that is used for the NTP server is
"MNT", and the IPv4 address of the NTP server and the broadcast address of the MNT port are the
same
•
"Yes" is selected for "Synchronize with NTP Server", the LAN port that is used for the NTP server is
"RMT", and the IPv4 address of the NTP server and the broadcast address of the RMT port are the
same
•
"Yes" is selected for "Synchronize with NTP Server" and one of the following conditions applies:
-
The IPv4 address for the NTP server and the local host address are the same
-
The IP address (IPv4 address or IPv6 address) for the NTP server and the network address are
the same
-
The IP address (IPv4 address or IPv6 address) for the NTP server and the IP address for the MNT
port are the same
-
The IP address (IPv4 address or IPv6 address) for the NTP server and the IP address for the RMT
port are the same
-
The IP address (IPv4 address) for the NTP server and the IP address for the FST port are the
same (only for the ETERNUS DX500 S3/DX600 S3 and the ETERNUS DX8700 S3/DX8900S3)
•
When "By day of the week" is selected for the range of daylight saving time, "Last" can be selected
to specify the start or end week.
•
When "By Date" is selected for the range of daylight saving time, "Last Day" can be selected to
specify the start or end date.
Summary of Contents for Eternus DX200F
Page 2: ...This page is intentionally left blank ...
Page 1082: ......