Appendix A Parameter List
A.4 Connectivity Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
874
•
Notify Vendor Unique Sense
•
Sense Data Conversion
Description
Select whether asynchronous sense reports module disconnection in the storage system
to the host ("Enable") or does not report module disconnection in the storage system to
the host ("Disable (Default)").
Input condition/
Display contents
•
Enable
•
Disable (Default)
A vendor unique sense code is used for sense data that is to be notified. Do not select "Enable" for this item if status
monitoring of the ETERNUS DX is not performed from the host.
Description
Select whether or not to send the unconverted sense data to the host.
Input condition/
Display contents
•
No Conversion (Default)
Sense data is sent to the host without any conversion.
•
Customize
Customized sense data is sent to the host.
Select "Customize" to display the sense data conversion setting field.
-
From SK/ASC/ASCQ
-
To SK/ASC/ASCQ
Customize the sense data.
Click the [Add] button. Enter SK/ASC/ASCQ of the conversion target in the "From"
field, and SK/ASC/ASCQ of the conversion destination in the "To" field. Specify
"From SK/ASC/ASCQ" and "To SK/ASC/ASCQ" values in pairs.
The sense data that matches the "From SK/ASC/ASCQ" value is changed to the
specified "To SK/ASC/ASCQ" value.
"*" indicates a wild-card, and targets all values. The maximum number of sense
data conversions is eight patterns.
Click each link to change the setting contents.
Sense Key (SK): SK indicates sense keys included in the sense information.
Additional Sense Code (ASC): ASC indicates sense codes included in the sense
information.
Additional Sense Code Qualifier (ASCQ): ASCQ indicates additional sense code
qualifier included in the sense information.
(Example 1) The sense information (4/f1/0) is converted to (4/f1/1) before
responding to the host.
From SK/ASC/ASCQ: 4/f1/0
To SK/ASC/ASCQ: 4/f1/1
(Example 2) The sense information (4/f1/0 - ff) is converted to (6/f1/0 - ff) before
responding to the host.
"*" indicates all patterns from "0" to "ff". The "*" part is not converted.
From SK/ASC/ASCQ: 4/f1/*
To SK/ASC/ASCQ: 6/f1/*
Summary of Contents for Eternus DX200F
Page 2: ...This page is intentionally left blank ...
Page 1082: ......