Appendix A Parameter List
A.7 Advanced Copy Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
950
•
For ETERNUS DX410/DX440/DX8100/DX8400/DX8700,
ETERNUS4000/ETERNUS8000 model 400/600/800/1200/2200,
ETERNUS4000/ETERNUS8000 model 300/500/700/900/1100/2100, or ETERNUS6000
Convert the FC port WWN to bit format and change the bit60 - 48 values to "0".
(Example 2)
When the FC port WWN is "2040000B5D6A0000", the storage system WWN is "2000000B5D6A0000".
The underlined value indicates bit60 - 48 in the following example:
Display screen of the FC port WWNs
The FC port WWNs are displayed in the following screens:
•
For the ETERNUS DX100 S3/DX200 S3, the ETERNUS DX500 S3/DX600 S3,
the ETERNUS DX8700 S3/DX8900 S3, or ETERNUS DX200F
Port information (FC) of the [Channel Adapter Detail] screen
•
For the ETERNUS DX90 S2, the ETERNUS DX410 S2/DX440 S2, or the ETERNUS DX8100 S2/DX8700 S2
Port information (FC) of the [Channel Adapter Detail] screen
•
For the ETERNUS DX90
Port status (FC) of the [Storage System Status] screen
•
For the ETERNUS DX410/DX440, the ETERNUS DX8100/DX8400/DX8700,
or the ETERNUS4000/ETERNUS8000
CA Detailed Information screen (FC) of the [Storage System Status] screen
•
For the ETERNUS6000
WWN list (FC) of the [Storage System Status] screen
●
Set Copy Path
•
Copy Path Information
Byte position
0
1
2
3
4
5
6
7
bit position
63 – 56
55–48
47–40
39–32
31–24
23–16
15–8
7–0
FC port WWN
(bit format)
2040000B5D6A0000
(0010 0000 0100 0000 0000 0000 0000 1011 0101 1101 0110 1010 0000 0000 0000 0000)
Storage system
WWN (bit format)
2000000B5D6A0000
(0010 0000 0000 0000 0000 0000 0000 1011 0101 1101 0110 1010 0000 0000 0000 0000)
Description
Select a copy path. Up to eight copy paths can be selected.
Checkboxes are displayed only for the combinations meeting all the following conditions
(combinations to which a copy path can be set):
•
The same port type (FC, iSCSI, or iSCSI-RA) is used for both the local storage system
and remote storage system.
•
The same IP version (v4, v6L, or v6C) is specified for the iSCSI ports that are used for
both the local and remote storage systems.
•
The port type is RA or CA/RA.
•
For the ETERNUS6000, the local storage system and the remote storage system have
different port usages (Initiator/Target).
Input condition/
Display contents
When the copy path is specified
Checkbox
•
Selected
•
Cleared