Chapter 4 Connectivity Management
4.1 Host Affinity Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
358
11
Confirm the modified host affinity setting and the path between the host and the CA port,
click the [Modify] button.
A confirmation screen appears.
12
Click the [OK] button.
The modification of the host affinity starts.
13
Click the [Done] button to return to the [Connectivity] screen.
End of procedure
■
When selecting a host affinity for "Host - CA Port"
The procedure to modify a host affinity is as follows:
Procedure
1
Select the host affinity to be modified, and click [Modify Host Affinity] in [Action].
If an error screen appears under the following conditions, check the parameter settings.
•
When the host interface type of the host group and the CA type of the CA port group do not match
Note that the CA types of "FCoE" and "FC" are regarded as the same CA type.
•
When the number of hosts exceeds the maximum number per CA port
•
When a host cannot recognize some LUNs
Summary of Contents for Eternus DX200F
Page 2: ...This page is intentionally left blank ...
Page 1082: ......