Chapter 3 Volume Management
3.16 Export Performance Information
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
321
3.16
Export Performance Information
This function exports the following performance information in a single operation and saves it as a text file.
•
Performance (Host I/O)
•
Performance (Advanced Copy)
•
Performance (CA)
•
Performance (CM)
•
Performance (Drive)
•
Performance (PCIe Flash Module)
The procedure to download the performance information is as follows:
Procedure
1
Click [Export Performance Info] in [Action].
•
If the performance monitoring is stopped, "0" is output for all the performance information.
•
Note that the dedicated information for the NAS system performance (such as Samba operations per
second and NFS operations per second) cannot be obtained with the ETERNUS Web GUI. Use ETERNUS CLI
to obtain this information.
•
"Performance (Host I/O)" is the performance information of volumes for Host I/O.
•
"Performance (Advanced Copy)" is the performance information of volumes for Advanced Copy.
•
The target CA for exporting information of "Performance (CA)" is FC, iSCSI, FCoE, and SAS. The perfor-
mance information for CAs that are in the ETERNUS DX is collected. Note that performance information
for FC port which port mode is "Initiator" cannot be obtained.
•
"Performance (PCIe Flash Module)" is obtained only when PFMs are installed in the ETERNUS DX500 S3/
DX600 S3 and the ETERNUS DX8700 S3/DX8900 S3.
•
The "Extreme Cache Cache Hit Rate" is obtained only when EXC or EXCP is enabled for the ETERNUS DX.
Note that a "-" (hyphen) is output for volumes where Extreme Cache and Extreme Cache Pool are dis-
abled. Refer to "Performance (Host I/O)" and "Performance (Advanced Copy)" in "ETERNUS Web GUI User’s
Guide (Operation)" for details.
Summary of Contents for Eternus DX200F
Page 2: ...This page is intentionally left blank ...
Page 1082: ......