Chapter 4 Connectivity Management
4.3 CA Port Group Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
434
•
The maximum number of port groups per storage system is 128, irrespective of the CA types.
•
The maximum number of ports per port group is 8.
•
A port can be a member of several port groups.
For details on the parameters for this function, refer to
"A.4.3.3 Create SAS Port Group" (page 840)
•
The ETERNUS DX500 S3/DX600 S3, the ETERNUS DX8700 S3/DX8900 S3, and the ETERNUS DX200F do not
support this function.
•
Registration of the port is necessary to create a port group. A port group cannot be created if the port to
be a member has not been registered from ETERNUS Web GUI.
•
A port in the affinity mode enabled (On) and a port in the affinity mode disabled (Off) cannot exist
together in a port group.
-
The affinity mode (On/Off) of a port group is decided when the host affinity setting has been
configured on the corresponding port group. All of the member ports in a port group have the same
affinity mode.
-
The affinity mode (On/Off) of a port group is not changed until the host affinity setting has been
released from the corresponding port group.
-
When one port is registered in several port groups, and the affinity setting has been configured on
one of the port groups including the corresponding port, the affinity setting is configured on all the
port groups, which include the corresponding port, and also on the member ports.
-
Ports without the host affinity setting can be members of a port group, regardless of whether the
affinity mode for the group is enabled (On) or disabled (Off).
•
To change the settings of a port groups, refer to
"4.3.6 Modify CA Port Group" (page 438)
.
•
To add a port to an existing port group, refer to
"4.3.6 Modify CA Port Group" (page 438)
.