CHAPTER 0 INTRODUCTION
0-6
Safety Precautions
0
■
Precautions on wiring
CAUTION
Never apply the commercial power supply to the U, V and W terminals of the servomotor.
It might cause fire and failure.
Do not connect the grounding (E) cable to the U, V and W terminals of the servomotor. Do not
connect the U, V and W terminals in inappropriate order.
It might cause fire or failure.
Do not connect the ground (E) to the servomotor side U, V, or W terminals, or connect the U, V, or
W terminals in the wrong order.
It may cause a fire or failure. Furthermore, there is a risk of damage to the customer's machine if
the motor malfunctions.
Always ensure that motor power cables are not connected incorrectly. If there is a motor power
cable wiring (U, V, W) phase interruption, the motor may not rotate, and an alarm (OL, OS, etc.)
may be detected even if a command is input.
Never perform a dielectric, Megger or buzzer test to the encoder terminals.
Otherwise the encoder will be damaged.
To perform a dielectric, Megger or buzzer test to the U, V and W terminals of the servomotor,
disconnect the servo amplifier.
Do not connect encoder terminals in inappropriate order.
Otherwise the encoder and servo amplifier will be damaged.
In an adverse power supply environment, insert a protective device such as the AC reactor so that
the voltage fluctuation is contained within the rating.
Otherwise the servo amplifier will be damaged.
Install a circuit breaker or similar safety devices for short circuits in external wiring.
There is a risk of fire or failure.
Do not remove the cover or disconnect the cable, connector or optional device with the servo
amplifier turned on.
There is a risk of electric shock to human body, product operation stop, and burnout.
Use the servo system under the specified voltage range.
Do not tie signal cables or route them in the same duct with main power cable or servo amplifier
motor output cable.
Use the designated wiring material. In particular, use the option cable or equivalent for the encoder
cable.
Do not insert a phase advance capacitor, various filter, reactor or similar on the output side of the
servo amplifier.
The servo amplifier cannot be fully protected from ground fault.
Ground
Be sure to connect the grounding terminal of the servo amplifier to a grounding electrode.
There is a risk of electric shock.
Summary of Contents for ALPHA7
Page 1: ......
Page 3: ...ii...
Page 22: ...0 1 CHAPTER 0 INTRODUCTION 0...
Page 36: ...1 1 CHAPTER 1 INSTALLATION 1...
Page 47: ...CHAPTER 1 INSTALLATION 1 12 Servo Amplifier 1...
Page 48: ...2 1 CHAPTER 2 WIRING 2...
Page 163: ...CHAPTER 2 WIRING 2 116 Safety Function 2...
Page 164: ...3 1 CHAPTER 3 OPERATION 3...
Page 192: ...4 1 CHAPTER 4 PARAMETER 4...
Page 317: ...CHAPTER 4 PARAMETER 4 126 Extension Function 2 Setting Parameters 4...
Page 318: ...5 1 CHAPTER 5 SERVO ADJUSTMENT 5...
Page 353: ...CHAPTER 5 SERVO ADJUSTMENT 5 36 Special Adjustment Vibration Suppression 5...
Page 354: ...6 1 CHAPTER 6 KEYPAD 6...
Page 408: ...7 1 CHAPTER 7 MAINTENANCE AND INSPECTION 7...
Page 434: ...8 1 CHAPTER 8 SPECIFICATIONS 8...
Page 460: ...9 1 CHAPTER 9 CHARACTERISTICS 9...
Page 472: ...10 1 CHAPTER 10 PERIPHERAL EQUIPMENT 10...
Page 516: ...11 1 CHAPTER 11 ABSOLUTE POSITION SYSTEM 11...
Page 523: ...CHAPTER 11 ABSOLUTE POSITION SYSTEM 11 8 Calculation of Battery Life 11...
Page 524: ...12 1 CHAPTER 12 POSITIONING DATA 12...
Page 540: ...13 1 CHAPTER 13 MODBUS RTU COMMUNICATION 13...
Page 579: ...CHAPTER 13 MODBUS RTU COMMUNICATION 13 40 Communications Procedures 13...
Page 580: ...14 1 CHAPTER 14 PC LOADER 14...
Page 614: ...STANDARDS COMPLIANCE CHAPTER 15 15...
Page 628: ...CHAPTER 16 APPENDIXES 16...
Page 661: ...CHAPTER 16 APPENDIXES 34 Product Warranty 16 16 7 Product Warranty...
Page 662: ......