6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
73
Object 6510h _ 34
h
: actual_dc_link_circuit_voltage
The actual voltage of the intermediate circuit in millivolts can be read out via the object
actual_dc_link_circuit_voltage
.
Sub-index
34
h
Description
actual_dc_link_circuit_voltage
Data Type
UINT32
Access
ro
PDO Mapping
yes
Units
mV
Value Range
--
Default Value
--
Object 6510
h
_ 35
h
: max_dc_link_circuit_voltage
The object
max_dc_link_circuit_voltage
specifies from which intermediate circuit voltage
the final stage, for safety reasons, is immediately switched off and an error message
issued.
Sub-index
35
h
Description
max_dc_link_circuit_voltage
Data Type
UINT32
Access
ro
PDO Mapping
no
Units
mV
Value Range
--
Default Value
device-dependent
Device type
Value
CMMP-AS-C2-3A
460000
CMMP-AS-C5-3A
460000
CMMP-AS-C5-11A-P3
800000
CMMP-AS-C10-11A-P3
800000
Summary of Contents for CMMP Series