
6. Setting Parameters
94
Festo P.BE-CMMP-CO-SW-EN 0708NH
Object 6066
h
: following_error_time_out
If a contouring error longer than defined in this object occurs, the related bit 13
following_error
is set in the
statusword
.
Index
6066
h
Name
following_error_time_out
Object code
VAR
Data Type
UINT16
Access
rw
PDO Mapping
yes
Units
ms
Value Range
0 … 27314
Default Value
0
Object 60FA
h
: control_effort
The output variable of the position controller can be read out via this object. This value is
fed internally as a command value to the velocity controller.
Index
60FA
h
Name
control_effort
Object code
VAR
Data Type
INT32
Access
ro
PDO Mapping
yes
Units
speed units
Value Range
--
Default Value
--
Object 6067
h
: position_window
With the object
position_window
a symmetrical area is defined around the target position
(
target_position
). If the actual position value (
position_actual_value
) lies within this area
for a certain time, the target position (
target_position
) is considered reached.
Index
6067
h
Name
position_window
Object code
VAR
Data Type
UINT32
Summary of Contents for CMMP Series
Page 2: ......