8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
199
Access
ro
PDO Mapping
yes
Units
motor_rated_torque / 1000
Value Range
--
Default Value
--
Object 6078
h
: current_actual_value
By means of this object, the motor's actual torque can be read out in thousanths of the
nominal torque (object
6075
h
).
Index
6078h
Name
current_actual_value
Object code
VAR
Data Type
INT16
Access
ro
PDO Mapping
yes
Units
motor_rated_current / 1000
Value Range
--
Default Value
--
Object 6079
h
: dc_link_circuit_voltage
The intermediate circuit voltage of the controller can be read out via this object.
The voltage is specified in the unit millivolt.
Index
6079
h
Name
dc_link_circuit_voltage
Object code
VAR
Data Type
UINT32
Access
ro
PDO Mapping
yes
Units
mV
Value Range
--
Default Value
--