5. Access Procedure
40
Festo P.BE-CMMP-CO-SW-EN 0708NH
4rd Receive PDO
Index
Comment
Type
Acc.
Default Value
1403
h
_00
h
number of entries
UINT8
ro
02
h
1403
h
_01
h
COB-ID used by PDO
UINT32 rw
C0000501
h
1403
h
_02
h
transmission type
UINT8
rw
FF
h
1603
h
_00
h
number of mapped objects
UINT8
rw
02
h
1603
h
_01
h
first mapped object
UINT32 rw
60400010
h
1603
h
_02
h
second mapped object
UINT32 rw
60FF0020
h
1603
h
_03
h
third mapped object
UINT32 rw
00000000
h
1603
h
_04
h
fourth mapped object
UINT32 rw
00000000
h
5.3.3
Activation of PDOs
For the motor controller to send or recieve PDOs, the following points must be met:
-
The object
number_of_mapped_objects
must not equal zero.
-
In the object
cob_id_used_for_pdos
, bit 31 must be deleted.
-
The communication status of the motor controller must be
operational
(see chapter 5.6, Network Management: NMT Service).
For parameters to be set for PDOs, the following points must be met:
-
The communication status of the motor controller must not be
operational
.
5.4
SYNC message
Several devices of a system can be synchronised with each other. To do this, one of the
devices (usually the higher-level controller) sends out synchronisation messages
periodically. All connected controllers receive these messages and use them for handling
the PDOs (see chapter 5.3).
Identifier: 80h
80
h
0
Data length
The identifier, on which the motor controller receives the SYNC message, is set
permanently to 080
h
. The identifier can be read out via the object
cob_id_sync
.
Index
1005
h
Name
cob_id_sync
Object code
VAR
Data Type
UINT32
Summary of Contents for CMMP Series
Page 2: ......