6. Setting Parameters
92
Festo P.BE-CMMP-CO-SW-EN 0708NH
Object 6062
h
: position_demand_value
The actual nominal position can be read out via this object. The curve generator feeds this
into the position controller.
Index
6062
h
Name
position_demand_value
Object code
VAR
Data Type
INT32
Access
ro
PDO Mapping
yes
Units
position units
Value Range
--
Default Value
--
Object 202D
h
: position_demand_sync_value
The actual nominal position can be read out via this object. This is defined by the object
2022
h
synchronization_encoder_select
(chapter 6.11). This object is specified in user-
defined increments.
Index
202D
h
Name
position_demand_sync_value
Object code
VAR
Data Type
INT32
Access
ro
PDO Mapping
no
Units
position units
Value Range
--
Default Value
--