Sub-index
01
h
Description
encoder_x10_resolution
Data Type
UINT32
Access
rw
PDO Mapping
no
Units
Increments (4 * resolution)
Value Range
depends on the encoder used
Default Value
depends on the encoder used
Sub-index
02
h
Description
encoder_x10_numerator
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
-32768 … 32767 (except 0)
Default Value
1
Sub-index
03
h
Description
encoder_x10_divisor
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
1 … 32767
Default Value
1
Sub-index
04
h
Description
encoder_x10_counter
Data Type
UINT32
Access
ro
PDO Mapping
yes
Units
Increments (4 * resolution)
Value Range
0 … (encoder_x10_resolution -1)
Default Value
--