6. Setting Parameters
122
Festo P.BE-CMMP-CO-SW-EN 0708NH
Bit
Value
Name
Manual
0
01
h
rising_edge_visible
Wenn rising_edge_occured = 1 => statusword bit 15 = 1
1
02
h
falling_edge_visible
When falling_edge_occured = 1 => statusword bit 15 = 1
Setting of the respective bits in
sample_control
resets the corresponding status bit in
sample_status
and enables sampling again in case of sampling "autolock".
Sub-index
04
h
Description
sample_control
Data Type
UINT8
Access
wo
PDO Mapping
yes
Units
--
Value Range
0 … 1, see table
Default Value
0
Bit
Value
Name
Manual
0
01
h
falling_edge_enable
Sampling in case of falling edge
1
02
h
rising_edge_enable
Sampling in case of rising edge
The following objects contain the sampled positions.
Sub-index
05
h
Description
sample_position_rising_edge
Data Type
INT32
Access
ro
PDO Mapping
yes
Units
position units
Value Range
--
Default Value
--
Sub-index
06
h
Description
sample_position_falling_edge
Data Type
INT32
Access
ro
PDO Mapping
yes
Units
position units
Value Range
--
Default Value
--