8. Operating modes
178
Festo P.BE-CMMP-CO-SW-EN 0708NH
Index
60C2
h
Name
interpolation_time_period
Object code
RECORD
No. of Elements 2
Sub-index
01
h
Description
ip_time_units
Data Type
UINT8
Access
rw
PDO Mapping
yes
Units
according to ip_time_index
Value Range
ip_time_index = -3: 1, 2 … 9, 10
ip_time_index = -4: 10, 20 … 90, 100
Default Value
--
Sub-index
02
h
Description
ip_time_index
Data Type
INT8
Access
rw
PDO Mapping
yes
Units
--
Value Range
-3, -4
Default Value
-3
Value
ip_time_units is specified in
-3
10
-3
seconds (ms)
-4
10
-4
seconds (0.1 ms)
A change in the synchronisation interval is effective only after a
reset. If the interpolation interval is to be changed via the CAN bus,
the parameter set must be saved and a reset performed.
Summary of Contents for CMMP Series